CÓDIGOS de ERROR Aire Acondicionados
Para los equipos split que traen este control remoto.
Señal H1 en la pantalla del control remoto
• Esta función de descongelamiento se presenta en otras referencias de aires que poseen unidad de calefacción.
------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------------------
LG
-------------------------------------------------------------------------------------------------------
Coventry - Electra
---------------------------------------------------------------------------------------------------------------
Descripción de fallas o comportamiento de protección (BGH)
BGH INVERTER SMART
_____________________________________________________________________________
ECOX
Codigos de Error y Procedimientos
Tabla de errores de Serie Inverter
_______________________________________
Descarga Aqui
_________________________________
__________________________________
Códigos Electra
Codigos Hitachi, TCL, Kelvinator, RCA, Daewoo
----------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------
HISENSE
Otras Marcas sin display
Surrey
Algunos modelos Inverter
-----------------------------------------------------------------------------------------------------------------
Lennox
---------------------------------------------------------------------------------------------------------------
MIRAGE
Otros Manuales Aqui
-----------------------------------------------------------
Mitsubishi
------------------------------------------------------------
Sanyo Inverter
Sanyo
Codigos error Sanyo Splits y VRF
Ver todos los codigos Aqui
__________________________________________________
Toshiba
Daikin
Codigos de autodiagnostico Aqui. Se hace con el control remoto
Panasonic
__________________________________________________________________
AUTODIAGNÓSTICO DE AVERÍAS EN EQUIPOS INVERTER DOMÉSTICOS PANASONIC
-----------------------------------------------------------------------------------------------------------
Samsung Multi split
Samsung
Samsung
Diagnostico de fallas Ver Aqui
---------------------------------------------------------------------------------------------------------------
* York *
Codigo de falla F6
Diagnostico = Falla del PG del forzador interior (Efecto Hall) Posiblemente el motor gire lento debido a envejecimiento del capacitor.
Codigo de falla F7
Diagnostico = Falla de sensor de temperatura de ambiente. (Room)
Codigo de falla F8
Diagnostico = Falla de sensor de serpentina (Pozo) en evaporador. (Coil)
Codigo de falla F9
Diagnostico = Falla de sensor de serpentina de unidad exterior.(Coil)
------------------------------------------------------------------------------------------------------------------------------------------------------------------
York VRF
--------------------------------------------------------------------------------------------
Midea air conditioner error codes
Indoor unit error code explanation:
R series:
DISPLAY | MALFUNCTION |
---|---|
E0 | EEPROM parameter error |
E1 | Indoor / outdoor units communication protection |
E2 | Zero-crossing signal error |
E3 | Fan speed out of control |
E5 | Open or short circuit of outdoor temperature sensor |
E6 | Open or short circuit of room or evaporator temperature sensor |
P0 | IGBT over-strong current protection |
P1 | Over voltage or too under voltage protection |
P2 | Temperature protection of compressor top. |
P4 | Inverter compressor drive error |
9V series
NO. | MALFUNCTION | DEF | TIMER | AUTO | RUN | DISPLAY DIGITAL TUBE |
---|---|---|---|---|---|---|
1 | EEPROM error | o | o | o | o | E0 |
2 | Indoor / outdoor units communication protection | * | * | * | * | E1 |
3 | Zero-crossing signal error | o | o | * | * | E2 |
4 | Indoor fan speed out of control | o | o | * | * | E3 |
5 | Outdoor unit temp. sensor or connector of temp. sensor is defective | x | o | x | * | E5 |
6 | Open or short circuit of room or evaporator temperature | o | o | o | * | E6 |
7 | Outdoor fan speed out of control | o | o | * | * | E7 |
8 | IBM malfunction or IGBT over-strong current protection | x | x | o | * | P0 |
9 | Over voltage or too under voltage protection | x | o | o | * | P1 |
10 | Temperature protection of compressor top. | o | x | x | * | P2 |
11 | Compressor position protection | o | x | * | * | P4 |
12 | Inverter module protection | x | o | * | * | P5 |
* Flash (at 0.5Hz, P5 at 0.25Hz) o light x (off)
9A series
NO. | MALFUNCTION | DEF | TIMER | AUTO | RUN | DISPLAY DIGITAL TUBE |
---|---|---|---|---|---|---|
1 | EEPROM error | o | o | o | o | E0 |
2 | Indoor / outdoor units communication protection | * | * | * | * | E1 |
3 | Zero-crossing signal error | o | o | * | * | E2 |
4 | Indoor fan speed out of control | o | o | * | * | E3 |
5 | Outdoor unit temp. sensor or connector of temp. sensor is defective | x | o | x | * | E5 |
6 | Open or short circuit of room or evaporator temperature | o | o | o | * | E6 |
7 | Outdoor fan speed out of control | * | o | * | * | E7 |
8 | IBM malfunction or IGBT over-strong current protection | x | x | o | * | P0 |
9 | Over voltage or too under voltage protection | x | o | o | * | P1 |
10 | Temperature protection of compressor top. | o | x | x | * | P2 |
11 | Compressor position protection | o | x | * | * | P4 |
12 | Inverter module protection | x | o | * | * | P5 |
* Flash (at 0.5Hz, P5 at 0.25Hz) o light x (off)
Cassette/Ceiling&Floor series:
OPERATION | TIMER | DE-FROST | ALARM | LED STATUS |
---|---|---|---|---|
* | x | x | x | Indoor room temp. sensor open or short-circuit |
x | x | * | x | Indoor pipe temp. sensor open or short-circuit |
x | * | x | x | Indoor and outdoor communication error |
x | x | x | * | Water level alarm |
* | * | x | x | EEPROM error |
* | x | x | o | Inverter module protection |
* | o | x | x | Outdoor sensor open or short circuit |
* | o | x | o | Outdoor voltage protection |
* | x | o | x | Compressor top temp. protection |
* | x | o | o | Mode conflict |
* | x | * | * | Outdoor current protection |
* flash, o light, x extinguished
Outdoor unit error code explanation:
For units (except M5OA-36HRDN1-Q model)
DISPLAY | LED STATUS |
---|---|
E0 | EEPROM error |
E1 | No A Indoor unit coil outlet temp. sensor or connector of sensor is defective |
E2 | No B Indoor unit coil outlet temp. sensor or connector of sensor is defective |
E3 | No C Indoor unit coil outlet temp. sensor or connector of sensor is defective |
E6 | No D Indoor unit coil outlet temp. sensor or connector of sensor is defective |
E4 | Outdoor unit temp. sensor or connector of temp. sensor is defective |
E5 | Compressor voltage protection |
E7 | Communication malfunction between outdoor main chip and compressor control chip |
P0 | Temperature protection of compressor discharge or compressor top. For M4OC-36HRDN1-Q,it only means compressor discharge temp.protection. |
P1 | High pressure protection(only for M4OC1-27HRDN1-Q, M4OC-36HRDN1-Q) |
P2 | Low pressure protection(only for M4OC1-27HRDN1-Q, M4OC-36HRDN1-Q) |
P3 | Compressor current protection |
P4 | Inverter module protection |
P6 | Condenser high-temperature protection |
For M5OA-36HRDN1-Q model
DISPLAY | LED STATUS |
---|---|
E0 | EEPROM error |
E1 | No A Indoor unit coil outlet temp. sensor or connector of sensor is defective |
E2 | Communication malfunction between outdoor unit and indoor units |
E3 | Communication malfunction between outdoor main chip and compressor control chip |
E4 | Outdoor unit temp. sensor or connector of temp. sensor is defective |
E5 | Compressor voltage protection |
E6 | PFC module protection |
P0 | Compressor top. temperature protection |
P1 | High pressure protection |
P2 | Low pressure protection |
P3 | Compressor current protection |
P4 | Compressor discharge high-temperature protection |
P5 | Condenser high-temperature protection |
P6 | Inverter module protection |
F1 | No A Indoor unit coil outlet temp. sensor or connector of sensor is defective |
F2 | No B Indoor unit coil outlet temp. sensor or connector of sensor is defective |
F3 | No C Indoor unit coil outlet temp. sensor or connector of sensor is defective |
F4 | No D Indoor unit coil outlet temp. sensor or connector of sensor is defective |
F5 | No E Indoor unit coil outlet temp. sensor or connector of sensor is defective |
Midea Codigos Inverter
Carrier
__________________________________________________
General Electric
__________________________________________________
Electrolux
Modelos:
EXH09HL1W - EXH12HL1W - EPH09MLIW - EPH12MLIW
C5: Avería del puente del conector.
Asegúrese de que el puente del conector hace contacto correctamente. Si fuera necesario, cambie la placa de circuitos antigua por una nueva.
F1: Avería del sensor de temperatura ambiente interior.
Asegúrese de que el sensor de temperatura ambiente interior.
F2: Avería del sensor de temperatura del evaporador.
Asegúrese de que el sensor de temperatura del evaporador está correctamente conectado.
Electrolux - Conqueror - BGH
---------------------------------------------------------------------------------
Westinghouse
Error en placas universales
---------------------------------------------------------------------------------
---------------------------------------------------------------------------------
Codigos de Error por Parpadeo Luminico AQUI
--------------------------------------------------------------------------------
Comentar es agradecer
No hay comentarios.:
Publicar un comentario